Medium
CVSS: 5.9
A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions). Affected devices do not properly check the integrity of firmware updates. This could allow a local attacker to upload a maliciousl…
Medium
CVSS: 6.7
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions with SINEMA Remote Connect Edge Client installed). Affected devices do transmit sensitive information in cleartext.
This could allow a privileged lo…
High
CVSS: 8.5
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions with SINEMA Remote Connect Edge Client installed). Affected devices do not properly sanitize configuration parameters.
This could allow a non-privil…
High
CVSS: 8.4
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions with SINEMA Remote Connect Edge Client installed). Affected devices are vulnerable to an authentication bypass.
This could allow a non-privileged lo…
Medium
CVSS: 5.4
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices are vulnerable to a stack-based buffer overflow.
This could allow a non-privileged local attacker to execute arbitrary…
Medium
CVSS: 5.4
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices are vulnerable to a stack-based buffer overflow.
This could allow a non-privileged local attacker to execute arbitrary…
Medium
CVSS: 5.3
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions). Affected devices do not properly handle multiple incoming Profinet packets received in rapid succession.
An unauthenticated remote attacker can ex…
Medium
CVSS: 5.3
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly validate incoming Profinet packets.
An unauthenticated remote attacker can exploit this flaw by sendin…
Medium
CVSS: 5.3
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly validate incoming Profinet packets.
An unauthenticated remote attacker can exploit this flaw by sendin…
Medium
CVSS: 5.3
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly validate incoming Profinet packets.
An unauthenticated remote attacker can exploit this flaw by sendin…
High
CVSS: 8.5
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly assign permissions to critical ressources.
This could allow a non-privileged local attacker to interac…
Medium
CVSS: 6.7
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices are vulnerable to path traversal attacks.
This could allow a privileged local attacker to restore backups that are out…
Medium
CVSS: 6.8
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly assign permissions to critical ressources.
This could allow a non-privileged local attacker to access…
High
CVSS: 8.7
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1). Affected products do not correctly invalidate user sessions upon user logout. This could allow…
High
CVSS: 7.3
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.14), Teamcenter Visualization V2312 (All versions < V2312.0010), Teamcenter Visualization V2406 (All versions < V2406.0008), Teamcenter Visualizat…
High
CVSS: 8.7
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (A…
High
CVSS: 8.7
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (A…
High
CVSS: 8.7
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (A…
Critical
CVSS: 9.3
A vulnerability has been identified in OZW672 (All versions < V6.0), OZW772 (All versions < V6.0). The web service of affected devices is vulnerable to SQL injection when checking authentication data. This could allow an unauthenticated rem…
Critical
CVSS: 10.0
A vulnerability has been identified in OZW672 (All versions < V8.0), OZW772 (All versions < V8.0). The web service in affected devices does not sanitize the input parameters required for the `exportDiagramPage` endpoint. This could allow an…