Opennetworking | Teknoloji dünyasından en güncel haberleri ve güvenlikle ilgili gelişmeleri takip edin.

Kategori: Opennetworking - CVE listesi
VENDOR 10 kayıt
High CVSS: 7.5

CVE-2025-65568

A denial-of-service vulnerability exists in the omec-project UPF (pfcpiface component) in version upf-epc-pfcpiface:2.1.3-dev. After PFCP association, a PFCP Session Establishment Request that includes a CreateFAR with an empty or truncated…
High CVSS: 7.5

CVE-2025-65567

A denial-of-service vulnerability exists in the omec-project UPF (pfcpiface component) in version upf-epc-pfcpiface:2.1.3-dev. After PFCP association, a specially crafted PFCP Session Establishment Request with a CreatePDR that contains a m…
High CVSS: 7.5

CVE-2025-65565

A denial-of-service vulnerability exists in the omec-project UPF (pfcpiface component) in version upf-epc-pfcpiface:2.1.3-dev. After PFCP association is established, a PFCP Session Establishment Request that is missing the mandatory F-SEID…
High CVSS: 7.5

CVE-2025-65564

A denial-of-service vulnerability exists in the omec-upf (upf-epc-pfcpiface) in version upf-epc-pfcpiface:2.1.3-dev. When the UPF receives a PFCP Association Setup Request that is missing the mandatory Recovery Time Stamp Information Elemen…
High CVSS: 7.5

CVE-2025-65563

A denial-of-service vulnerability exists in the omec-project UPF (component upf-epc/pfcpiface) up to at least version upf-epc-pfcpiface:2.1.3-dev. When the UPF receives a PFCP Association Setup Request that is missing the mandatory NodeID I…
Medium CVSS: 5.6

CVE-2024-53423

An issue in Open Network Foundation ONOS v2.7.0 allows attackers to cause a Denial of Service (DoS) via supplying crafted packets.
Critical CVSS: 9.8

CVE-2023-41591

An issue in Open Network Foundation ONOS v2.7.0 allows attackers to create fake IP/MAC addresses and potentially execute a man-in-the-middle attack on communications between fake and real hosts.
Critical CVSS: 9.1

CVE-2025-29312

An issue in onos v2.7.0 allows attackers to trigger unexpected behavior within a device connected to a legacy switch via changing the link type from indirect to direct.
High CVSS: 7.5

CVE-2025-29311

Limited secret space in LLDP packets used in onos v2.7.0 allows attackers to obtain the private key via a bruteforce attack. Attackers are able to leverage this vulnerability into creating crafted LLDP packets.
Critical CVSS: 9.8

CVE-2025-29310

An issue in onos v2.7.0 allows attackers to trigger a packet deserialization problem when supplying a crafted LLDP packet. This vulnerability allows attackers to execute arbitrary commands or access network information.