Nshield 5c Firmware | Teknoloji dünyasından en güncel haberleri ve güvenlikle ilgili gelişmeleri takip edin.

Kategori: Nshield 5c Firmware - CVE listesi
PRODUCT 12 kayıt
Medium CVSS: 4.6

CVE-2025-59704

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow an attacker to gain access the the BIOS menu because is has no password.
Critical CVSS: 9.1

CVE-2025-59703

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a Physically Proximate Attacker to access the internal components of the appliance, without leaving tamper evidence. To exploit this, the attacker need…
Medium CVSS: 6.8

CVE-2025-59705

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a Physically Proximate Attacker to Escalate Privileges by enabling the USB interface through chassis probe insertion during system boot, aka "Unauthori…
High CVSS: 7.2

CVE-2025-59702

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker with elevated privileges to falsify tamper events by accessing internal components.
Low CVSS: 3.9

CVE-2025-59700

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker with root access to modify the Recovery Partition (because of a lack of integrity protection).
Medium CVSS: 6.8

CVE-2025-59699

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker to escalate privileges by booting from a USB device with a valid root filesystem. This occurs because of insecure defau…
Medium CVSS: 6.8

CVE-2025-59698

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, might allow a physically proximate attacker to gain access to the EOL legacy bootloader.
High CVSS: 7.2

CVE-2025-59697

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker to escalate privileges by editing the Legacy GRUB bootloader configuration to start a root shell upon boot of the host…
Low CVSS: 3.2

CVE-2025-59696

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a physically proximate attacker to modify or erase tamper events via the Chassis management board.
Critical CVSS: 9.8

CVE-2025-59695

Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a user with OS root access to alter firmware on the Chassis Management Board (without Authentication). This is called F04.
Medium CVSS: 6.8

CVE-2025-59694

The Chassis Management Board in Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allows a physically proximate attacker to persistently modify firmware and influence the (insecurely configured) appliance bo…
Critical CVSS: 9.8

CVE-2025-59693

The Chassis Management Board in Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allows a physically proximate attacker to obtain debug access and escalate privileges by bypassing the tamper label and openi…