Ac8 Firmware | Teknoloji dünyasından en güncel haberleri ve güvenlikle ilgili gelişmeleri takip edin.

Kategori: Ac8 Firmware - CVE listesi
PRODUCT 29 kayıt
High CVSS: 8.9

CVE-2026-4254

A weakness has been identified in Tenda AC8 up to 16.03.50.11. This vulnerability affects the function doSystemCmd of the file /goform/SysToolChangePwd of the component HTTP Endpoint. This manipulation of the argument local_2c causes stack-…
Medium CVSS: 5.1

CVE-2026-4253

A security flaw has been discovered in Tenda AC8 16.03.50.11. This affects the function route_set_user_policy_rule of the file /cgi-bin/UploadCfg of the component Web Interface. The manipulation of the argument wans.policy.list1 results in…
High CVSS: 8.9

CVE-2026-4252

A vulnerability was identified in Tenda AC8 16.03.50.11. Affected by this issue is the function check_is_ipv6 of the component IPv6 Handler. The manipulation leads to reliance on ip address for authentication. It is possible to initiate the…
High CVSS: 7.4

CVE-2026-3044

A vulnerability has been found in Tenda AC8 16.03.34.06. This affects the function webCgiGetUploadFile of the file /cgi-bin/UploadCfg of the component Httpd Service. The manipulation of the argument boundary leads to stack-based buffer over…
High CVSS: 7.4

CVE-2026-2203

A flaw has been found in Tenda AC8 16.03.33.05. Affected by this vulnerability is an unknown functionality of the file /goform/fast_setting_wifi_set of the component Embedded Httpd Service. This manipulation of the argument timeZone causes…
High CVSS: 7.4

CVE-2026-2202

A vulnerability was detected in Tenda AC8 16.03.33.05. Affected is the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet of the component httpd. The manipulation of the argument shareSpeed results in buffer overflow. The attac…
High CVSS: 7.4

CVE-2025-12618

A vulnerability has been found in Tenda AC8 16.03.34.06. This impacts an unknown function of the file /goform/DatabaseIniSet. The manipulation of the argument Time leads to buffer overflow. The attack can be initiated remotely. The exploit…
High CVSS: 7.5

CVE-2025-61498

A buffer overflow in the UPnP service of Tenda AC8 Hardware v03.03.10.01 allows attackers to cause a Denial of Service (DoS) via supplying a crafted packet.
High CVSS: 7.5

CVE-2025-55852

Tenda AC8 v16.03.34.06 is vulnerable to Buffer Overflow in the formWifiBasicSet function via the parameter security or security_5g.
Medium CVSS: 6.5

CVE-2025-51089

Tenda AC8V4 V16.03.34.06` was discovered to contain heap overflow at /goform/GetParentControlInfo.The manipulation of the argument `mac` leads to heap-based buffer overflow.
Medium CVSS: 5.3

CVE-2025-51088

Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/WifiGuestSet. The manipulation of the argument `shareSpeed` leads to stack-based buffer overflow.
High CVSS: 8.6

CVE-2025-51087

Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow.
Medium CVSS: 5.3

CVE-2025-51085

Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/SetSysTimeCfg. The manipulation of the argument `timeZone` and `timeType` leads to stack-based buffer overflow.
Medium CVSS: 5.3

CVE-2025-51082

Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/fast_setting_wifi_set. The manipulation of the argument `timeZone` leads to stack-based buffer overflow.
High CVSS: 7.4

CVE-2025-5799

A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto lead…
High CVSS: 7.4

CVE-2025-5798

A vulnerability was found in Tenda AC8 16.03.34.09. It has been classified as critical. Affected is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeType leads to stack-based buffer overflo…
High CVSS: 8.7

CVE-2025-4368

A vulnerability, which was classified as critical, was found in Tenda AC8 16.03.34.06. Affected is the function formGetRouterStatus of the file /goform/MtuSetMacWan. The manipulation of the argument shareSpeed leads to buffer overflow. It i…
Critical CVSS: 9.8

CVE-2025-29100

Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the fromSetRouteStatic function via the parameter list.
High CVSS: 7.5

CVE-2025-29101

Tenda AC8V4.0 V16.03.34.06 was discovered to contain a stack overflow via the deviceid parameter in the get_parentControl_list_Info function.
Medium CVSS: 6.5

CVE-2025-29118

Tenda AC8 V16.03.34.06 was discovered to contain a stack overflow via the src parameter in the function sub_47D878.