Ac5 Firmware | Teknoloji dünyasından en güncel haberleri ve güvenlikle ilgili gelişmeleri takip edin.

Kategori: Ac5 Firmware - CVE listesi
PRODUCT 10 kayıt
High CVSS: 7.4

CVE-2026-4906

A vulnerability was determined in Tenda AC5 15.03.06.47. The affected element is the function decodePwd of the file /goform/WizardHandle of the component POST Request Handler. Executing a manipulation of the argument WANT/WANS can lead to s…
High CVSS: 7.4

CVE-2026-4905

A vulnerability was found in Tenda AC5 15.03.06.47. Impacted is the function formWifiWpsOOB of the file /goform/WifiWpsOOB of the component POST Request Handler. Performing a manipulation of the argument index results in stack-based buffer…
High CVSS: 7.4

CVE-2026-4904

A vulnerability has been found in Tenda AC5 15.03.06.47. This issue affects the function formSetCfm of the file /goform/setcfm of the component POST Request Handler. Such manipulation of the argument funcpara1 leads to stack-based buffer ov…
High CVSS: 7.4

CVE-2026-4903

A flaw has been found in Tenda AC5 15.03.06.47. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex of the component POST Request Handler. This manipulation of the argument PPPOEPassword causes stack-based…
High CVSS: 7.4

CVE-2026-4902

A vulnerability was detected in Tenda AC5 15.03.06.47. This affects the function fromAddressNat of the file /goform/addressNat of the component POST Request Handler. The manipulation of the argument page results in stack-based buffer overfl…
High CVSS: 7.4

CVE-2025-6887

A vulnerability was found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this issue is some unknown functionality of the file /goform/SetSysTimeCfg. The manipulation of the argument time/timeZone leads to stack-based buffe…
High CVSS: 7.4

CVE-2025-6886

A vulnerability has been found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime l…
High CVSS: 7.4

CVE-2025-5863

A vulnerability was found in Tenda AC5 15.03.06.47. It has been classified as critical. Affected is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer…
High CVSS: 7.4

CVE-2025-5795

A vulnerability, which was classified as critical, was found in Tenda AC5 1.0/15.03.06.47. This affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. It is p…
High CVSS: 7.4

CVE-2025-5794

A vulnerability, which was classified as critical, has been found in Tenda AC5 15.03.06.47. Affected by this issue is the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffe…