Kategori: Ac10 Firmware - CVE listesi
PRODUCT 18 kayıt
Medium CVSS: 6.5

CVE-2025-67074

A Buffer overflow vulnerability in function fromAdvSetMacMtuWan of bin httpd in Tenda AC10V4.0 V16.03.10.20 allows remote attackers to cause denial of service and possibly code execution by sending a post request with a crafted payload (fie…
Critical CVSS: 9.8

CVE-2025-67073

A Buffer overflow vulnerability in function fromAdvSetMacMtuWan of bin httpd in Tenda AC10V4.0 V16.03.10.20 allows remote attackers to cause denial of service and possibly code execution by sending a post request with a crafted payload (fie…
High CVSS: 7.4

CVE-2025-12622

A vulnerability was determined in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function formSysRunCmd of the file /goform/SysRunCmd. This manipulation of the argument getui causes buffer overflow. The attack may be initiate…
Low CVSS: 2.0

CVE-2025-9309

A vulnerability was found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /etc_ro/shadow of the component MD5 Hash Handler. Performing manipulation results in hard-coded credentials. The attack needs to be approached…
High CVSS: 7.4

CVE-2025-8178

A vulnerability classified as critical has been found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /goform/RequestsProcessLaid. The manipulation of the argument device1D leads to heap-based buffer overflow. It is p…
High CVSS: 8.7

CVE-2025-5629

A vulnerability, which was classified as critical, was found in Tenda AC10 up to 15.03.06.47. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg of the component HTTP Handler. The manipulation of the argument s…
High CVSS: 8.7

CVE-2025-4896

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is some unknown functionality of the file /goform/UserCongratulationsExec. The manipulation of the argument getuid leads to buffer overfl…
Medium CVSS: 5.4

CVE-2025-44175

Tenda AC10 v4 V16.03.10.13 is vulnerable to Buffer Overflow in the GetParentControlInfo function.
Critical CVSS: 9.8

CVE-2025-45779

Tenda AC10 V1.0re_V15.03.06.46 is vulnerable to Buffer Overflow in the formSetPPTPUserList handler via the list POST parameter.
High CVSS: 7.5

CVE-2025-25455

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via wanMTU2.
High CVSS: 7.5

CVE-2025-25454

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via wanSpeed2.
High CVSS: 7.5

CVE-2025-25457

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via cloneType2.
Medium CVSS: 4.6

CVE-2025-25458

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via serverName2.
Medium CVSS: 4.6

CVE-2025-25453

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via serviceName2.
Critical CVSS: 9.8

CVE-2025-25456

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via mac2.
High CVSS: 8.7

CVE-2025-3161

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function ShutdownSetAdd of the file /goform/ShutdownSetAdd. The manipulation of the argument list leads to stack-based buffer overflow. T…
Critical CVSS: 9.8

CVE-2025-25675

Tenda AC10 V1.0 V15.03.06.23 has a command injection vulnerablility located in the formexeCommand function. The str variable receives the cmdinput parameter from a POST request and is later assigned to the cmd_buf variable, which is directl…
Critical CVSS: 9.8

CVE-2025-25674

Tenda AC10 V1.0 V15.03.06.23 is vulnerable to Buffer Overflow in form_fast_setting_wifi_set via the parameter ssid.