CWE-119 | Teknoloji dünyasından en güncel haberleri ve güvenlikle ilgili gelişmeleri takip edin.

Kategori: CWE-119 - CVE listesi
CWE 1509 kayıt
High CVSS: 7.4

CVE-2026-3809

A flaw has been found in Tenda FH1202 1.2.0.14(408). The impacted element is the function fromNatStaticSetting of the file /goform/NatSaticSetting. Executing a manipulation of the argument page can lead to stack-based buffer overflow. The a…
High CVSS: 7.4

CVE-2026-3808

A vulnerability was detected in Tenda FH1202 1.2.0.14(408). The affected element is the function formWebTypeLibrary of the file /goform/webtypelibrary. Performing a manipulation of the argument webSiteId results in stack-based buffer overfl…
High CVSS: 7.4

CVE-2026-3807

A security vulnerability has been detected in Tenda FH1202 1.2.0.14(408). Impacted is the function formWrlsafeset of the file /goform/AdvSetWrlsafeset. Such manipulation of the argument mit_ssid/mit_ssid_index leads to stack-based buffer ov…
High CVSS: 7.4

CVE-2026-3804

A security flaw has been discovered in Tenda i3 1.0.0.6(2204). This vulnerability affects the function formWifiMacFilterSet of the file /goform/WifiMacFilterSet. The manipulation of the argument index results in stack-based buffer overflow.…
High CVSS: 7.4

CVE-2026-3803

A vulnerability was identified in Tenda i3 1.0.0.6(2204). This affects the function formWifiMacFilterGet of the file /goform/WifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to in…
High CVSS: 7.4

CVE-2026-3802

A vulnerability was determined in Tenda i3 1.0.0.6(2204). Affected by this issue is the function formexeCommand of the file /goform/exeCommand. Executing a manipulation of the argument cmdinput can lead to stack-based buffer overflow. The a…
High CVSS: 7.4

CVE-2026-3801

A vulnerability was found in Tenda i3 1.0.0.6(2204). Affected by this vulnerability is the function formSetAutoPing of the file /goform/setAutoPing. Performing a manipulation of the argument ping1/ping2 results in stack-based buffer overflo…
High CVSS: 7.4

CVE-2026-3799

A flaw has been found in Tenda i3 1.0.0.6(2204). This impacts the function formSetCfm of the file /goform/setcfm. This manipulation of the argument funcpara1 causes stack-based buffer overflow. Remote exploitation of the attack is possible.…
High CVSS: 7.4

CVE-2026-3769

A vulnerability was detected in Tenda F453 1.0.0.3. Affected by this issue is the function WrlclientSet of the file /goform/WrlclientSet. The manipulation of the argument GO results in stack-based buffer overflow. The attack can be executed…
High CVSS: 7.4

CVE-2026-3768

A security vulnerability has been detected in Tenda F453 1.0.0.3. Affected by this vulnerability is the function formWrlExtraSet of the file /goform/WrlExtraSet. The manipulation of the argument GO leads to stack-based buffer overflow. Remo…
High CVSS: 7.4

CVE-2026-3732

A security vulnerability has been detected in Tenda F453 1.0.0.3. This affects the function strcpy of the file /goform/exeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to initiate th…
Medium CVSS: 6.9

CVE-2026-3731

A weakness has been identified in libssh up to 0.11.3. The impacted element is the function sftp_extensions_get_name/sftp_extensions_get_data of the file src/sftp.c of the component SFTP Extension Name Handler. Executing a manipulation of t…
High CVSS: 7.4

CVE-2026-3729

A vulnerability was identified in Tenda F453 1.0.0.3/3.As. Impacted is the function fromPptpUserAdd of the file /goform/PPTPDClient. Such manipulation of the argument username/opttype leads to stack-based buffer overflow. The attack can be…
High CVSS: 7.4

CVE-2026-3728

A vulnerability was determined in Tenda F453 1.0.0.3/1.If. This issue affects the function fromSetCfm of the file /goform/setcfm. This manipulation of the argument funcname/funcpara1 causes stack-based buffer overflow. Remote exploitation o…
High CVSS: 7.4

CVE-2026-3727

A vulnerability was found in Tenda F453 1.0.0.3. This vulnerability affects the function sub_3C6C0 of the file /goform/QuickIndex. The manipulation of the argument mit_linktype/PPPOEPassword results in stack-based buffer overflow. The attac…
High CVSS: 7.4

CVE-2026-3726

A vulnerability has been found in Tenda F453 1.0.0.3. This affects the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be…
High CVSS: 7.4

CVE-2026-3715

A vulnerability was found in Wavlink WL-WN579X3-C 231124. This affects the function sub_40139C of the file /cgi-bin/firewall.cgi. Performing a manipulation of the argument del_flag results in stack-based buffer overflow. It is possible to i…
Medium CVSS: 4.8

CVE-2026-3713

A flaw has been found in pnggroup libpng up to 1.6.55. Affected by this vulnerability is the function do_pnm2png of the file contrib/pngminus/pnm2png.c of the component pnm2png. This manipulation of the argument width/height causes heap-bas…
High CVSS: 8.9

CVE-2026-3703

A flaw has been found in Wavlink NU516U1 251208. This affects the function sub_401A10 of the file /cgi-bin/login.cgi. Executing a manipulation of the argument ipaddr can lead to out-of-bounds write. The attack may be performed from remote.…
High CVSS: 7.4

CVE-2026-3701

A security vulnerability has been detected in H3C Magic B1 up to 100R004. Affected by this vulnerability is the function Edit_BasicSSID_5G of the file /goform/aspForm. Such manipulation of the argument param leads to buffer overflow. The at…